Publications

  • Validation of PTV margin for Gamma Knife Icon frameless treatment using a PseudoPatient® Prime anthropomorphic phantom
    Eun Young Han, Parmeswaran Diagaradjane, Dershan Luo, Yao Ding, Georgios Kalaitzakis, Emmanouil Zoros, Kyveli Zourari, Themistoklis Boursianis, Evangelos Pappas, Zhifei Wen, Jihong Wang, Tina Marie Briere
    Journal of applied Clinical Medical Physics, (2020)
  • Dosimetric performance of the Elekta Unity MR-linac system: 2D and 3D dosimetry in anthropomorphic inhomogeneous geometry
    E Pappas, G Kalaitzakis , T Boursianis , E Zoros , KZourari , E P Pappas , D Makris , I Seimenis , E Efstathopoulos and T G Maris
    Phys.Med.Biol.,November 2019, (1)
  • Characterization of a novel 3D printed patient-specific phantom for quality assurance in cranial stereotactic radiosurgery applications
    Makris D. N., Pappas E. P., Zoros E., Papanikolaou N., Saenz D. L., Kalaitzakis G., Zourari K., Efstathopoulos E., Maris T.G., Pappas E.
    Phys. Med. Biol., April, (2019)
  • Dosimetric and localization accuracy of Elekta high definition dynamic radiosurgery
    Saenz D., Ying Lia, Rasmussen K., Stathakis S., Pappas E., Papanikolaou N.
    Physica Medica, (2018)
  • Gel dosimetry for three dimensional proton range measurements in anthropomorphic geometries
    Hillbrand M., Landry G., Ebert S., Dedes G., Pappas E. P., Kalaitzakis G., Kurz C., Würl M., Englbrecht F., Dietrich O., Makris D., Pappas E., Parodi K.
    Zeitschrift für Medizinische Physik, (2018)
  • QA for SBRT of Spine Lesions: Introducing a Novel 3D Gel Dosimeter for Spatial and Dosimetric End-to-End Testing
    Saenz D., Rasmussen K., Pappas E., Kirby N., Stathakis S., Shi Jr Z., Papanikolaou N.
    International Journal of Radiation Oncology, Biology, Physics, (2018)
  • 3D Gel Dosimetry for Commissioning and Routing QA in Mono and Poly-Isocentric SRS
    Papanikolaou K., Saenz D., Rasmussen K., Kirby N., Stathakis S., Pappas E., Li Y.
    International Journal of Radiation Oncology, Biology, Physics, (2018)
  • Personalized End-to-End QA in Cranial SRS: Evaluation of the Phantom-to-Patient Dosimetric Equivalency of a 3D Printed Phantom using Film Dosimetry
    Pappas E. P., Makris D., Zoros E., Kalaitzakis G., Boursianis T., Papanikolaou N., Hourdakis C., Zourari K., Lahanas V., Maris T.G., Efstathopoulos E., Pappas E.
    International Journal of Radiation Oncology, Biology, Physics, (2018)
  • Phantom and Patient Based Estimation of the Targeting Accuracy of a Robotic Radiosurgery System
    E Pantelis, A Moutsatsos, C Antypas, E Zoros, P Pantelakos, L Lekas, P Romanelli, K Zourari, CJ Hourdakis
    Medical Physics, (2018)
  • On the total system error of a robotic radiosurgery system: Phantom measurements, clinical evaluation and long-term analysis
    E Pantelis, A S Moutsatsos, C Antypas, E Zoros, P Pantelakos, L Lekas, P Romanelli, K Zourari and C J Hourdakis
    Physics in Medicine & Biology, (2018)